All tests / EPA 608 technician certification test / Type I: small appliances
EPA 608 technician certification test: Type I: small appliances practice
45 practice questions on Type I: small appliances for the EPA 608 technician certification test. Each answer comes with an explanation and the official source.
Tests recovery standards, evacuated percentages, pierce-valve limits, and safe service practices for small appliances holding 5 pounds or less of refrigerant.
Sample questions
What is required before a person may maintain, service, repair, or dispose of an appliance containing a class I or class II refrigerant?
- Registration of the appliance with the state government
- A written permit from the local environmental agency
- The presence of a second certified technician to witness the work
- The use of recovery or recycling equipment certified for that type of refrigerant and appliance (correct answer)
The regulations prohibit maintaining, servicing, repairing, or disposing of an appliance containing a class I or class II refrigerant without using recovery and/or recycling equipment that is certified for that type of refrigerant and appliance.
(b) No person may maintain, service, repair, or dispose of an appliance containing a class I or class II refrigerant or a non-exempt substitute refrigerant without: (1) Observing the applicable practices in §§ 82.155, 82.156, and 82.157; and (2) Using recovery and/or recycling equipment that is certified for that type of refrigerant and appliance under § 82.158.
Which of the following is a requirement for a buyer to purchase a non-exempt substitute refrigerant for use as a refrigerant?
- The buyer must provide a list of all appliances they own
- The buyer must have a business license for at least five years
- The buyer must be certified as a Type I, Type II, Type III, or Universal technician (correct answer)
- The buyer must complete a training course on environmental law
A person may not sell or distribute a non-exempt substitute for use as a refrigerant unless the buyer has been certified as a Type I, Type II, Type III, or Universal technician.
(c) Sales restriction. (1) No person may sell or distribute, or offer for sale or distribution, any substance that consists in whole or in part of a class I or class II substance or, starting on January 1, 2018, any non-exempt substitute for use as a refrigerant unless: (i) The buyer has been certified as a Type I, Type II, Type III, or Universal technician under § 82.161;
What is the maximum amount of refrigerant a small appliance can contain to be classified as such?
- 2 pounds
- 10 pounds
- 15 pounds
- 5 pounds (correct answer)
A small appliance is defined as an appliance that is fully manufactured, charged, and hermetically sealed in a factory with five pounds or less of refrigerant.
Small appliance means any appliance that is fully manufactured, charged, and hermetically sealed in a factory with five (5) pounds or less of refrigerant
Which of the following activities is considered a violation of the integrity of the refrigerant circuit?
- Adding or removing refrigerant (correct answer)
- Painting the appliance
- Replacing insulation on a length of pipe
- Rewiring an external electrical circuit
Activities reasonably expected to violate the integrity of the refrigerant circuit include adding or removing refrigerant. Painting, rewiring, and replacing insulation are not considered to violate the integrity of the circuit.
Activities reasonably expected to violate the integrity of the refrigerant circuit include but are not limited to: Attaching or detaching hoses and gauges to and from the appliance; adding or removing refrigerant; adding or removing components; and cutting the refrigerant line.
What is the term for a length of tubing that provides access to the refrigerant inside a small appliance and can be resealed after service?
- Hermetic port
- Service valve
- Process stub (correct answer)
- Access fitting
A process stub is a length of tubing that provides access to the refrigerant inside a small appliance or room air conditioner and that can be resealed at the conclusion of repair or service.
Process stub means a length of tubing that provides access to the refrigerant inside a small appliance or room air conditioner and that can be resealed at the conclusion of repair or service.
Other topics on this test
-
Core66 questionsPractice
-
Type II: high-pressure appliances38 questionsPractice
-
Type III: low-pressure appliances48 questionsPractice
Sources
Current text, retrieved November 16, 2026
Tests are given by EPA-approved certifying programs, not by EPA itself. EPA does not issue certification cards. ExamVerdict is not affiliated with US Environmental Protection Agency (EPA), given by EPA-approved certifying programs. Check the official material before test day.