All tests / EPA 608 technician certification test
EPA 608 technician certification test practice
Technicians who maintain, service, repair or dispose of equipment that could release refrigerant must be certified under Section 608 of the Clean Air Act. Certification is by type: Type I for small appliances, Type II for high-pressure appliances, Type III for low-pressure appliances, and Universal for all three.
- Questions
- At least 25 core plus 25 per type; 100 for Universal
- To pass
- 70% (84% for mail-in Type I)
- Format
- Closed-book and proctored for Type II, Type III and Universal
- Rule
- 40 CFR Part 82, Subpart F
- Pass mark
- 70%
- Run by
- US Environmental Protection Agency (EPA), given by EPA-approved certifying programs
- Practice questions here
- 197
Each test has at least 25 questions from the core group and 25 from each technical group, and Universal is 100 questions. The passing score is 70 percent, or 84 percent for Type I tests taken in the mail-in format. All of this is set in 40 CFR Part 82, Subpart F, which is the text every practice question here is written from.
Who needs Section 608 certification
Section 608 of the Clean Air Act makes it illegal to vent most refrigerants into the air. Under the EPA's rules in 40 CFR Part 82, Subpart F, anyone who maintains, services, repairs or disposes of equipment in ways that could release refrigerant must be certified. That covers HVAC and refrigeration technicians, appliance repairers, and many maintenance staff in buildings, supermarkets and factories. Certification is also what lets you buy most refrigerants: sellers may only sell them to certified technicians.
The four certifications
The certification you need depends on the equipment you work on:
- Type I: small appliances, factory-sealed systems with 5 pounds of refrigerant or less, such as household refrigerators, window air conditioners and dehumidifiers.
- Type II: high-pressure and very high-pressure appliances, such as residential split systems, heat pumps and most commercial refrigeration.
- Type III: low-pressure appliances, mainly large centrifugal chillers.
- Universal: all three types.
Every test includes a Core section on rules and principles that apply to everyone: ozone depletion and climate effects, the venting prohibition, recovery and recycling, the three Rs, leak repair, safety and shipping of cylinders.
How the test works
You do not take the test from the EPA. It is given by EPA-approved certifying programs, such as trade schools, unions, supply houses and national organisations, each with its own schedule and fee.
Each section has 25 questions. A Type I, Type II or Type III certification means passing Core plus that type, and Universal means passing all four sections, 100 questions in total. The passing score is 70 percent for each section. Type II, Type III and Universal tests must be closed-book and proctored. Type I can also be offered in a non-proctored format, but then the passing score is 84 percent.
Certifying programs generally let you keep the sections you pass. If you pass Core and Type II but fail Type III, you normally only retake Type III.
Your certificate
Section 608 certification does not expire. You receive a wallet card or certificate from the program that tested you, and you must keep a copy at your place of business. If you lose it, the same certifying program can replace it.
What is tested most
Questions return again and again to a few areas:
- Recovery: required evacuation levels for recovery equipment, which depend on the type of appliance and when the recovery equipment was made.
- Leaks: leak rate thresholds that trigger a repair for comfort cooling, commercial refrigeration and industrial process equipment, and the deadlines for repairs and verification tests.
- Recordkeeping: what technicians and owners must record and how long to keep it.
- Disposal: the safe-disposal requirements for small appliances, and the verification statements in the disposal chain.
- Safety: pressures, cylinder handling, never heating a cylinder with an open flame, and the dangers of refrigerant in enclosed spaces.
How to use this practice test
Every question here is written from the regulation itself, 40 CFR Part 82 Subpart F, and each answer shows the passage it rests on. That makes it a good check on the exact rules. Commercial study guides often explain the science better, so if a principle is unclear, look it up there and come back.
Start with Core: it is on every test and it holds the definitions the other sections rely on. Then practise the type you need with topic drills. When you score 80 percent or more on full 25-question runs in each section, you are ready to book with a certifying program. If you are aiming for Universal, practise all four sections on the same day, the way the real exam runs.
How this practice works
Pick a mode
Untimed mode is the default. Choose timed mode to match the real clock, or study mode to read answers without scoring.
See the official source
After every answer you see the explanation and the exact passage or key from US Environmental Protection Agency (EPA), given by EPA-approved certifying programs.
Review your misses
Your browser remembers your best score and missed questions locally so you can drill weak topics or practise only your mistakes.
Practice by topic
-
Core66 questionsPractice
-
Type I: small appliances45 questionsPractice
-
Type II: high-pressure appliances38 questionsPractice
-
Type III: low-pressure appliances48 questionsPractice
Sample questions
For a system with multiple circuits, how is each independent circuit considered?
- An unapproved component
- A batch of refrigerant
- A separate appliance (correct answer)
- A class I substance
For a system with multiple circuits, each independent circuit is considered a separate appliance.
For a system with multiple circuits, each independent circuit is considered a separate appliance.
What is the maximum time limit a person may remain an apprentice from the date of first registering?
- Six months
- Five years
- One year
- Two years (correct answer)
A person may only be an apprentice for two years from the date of first registering with that office.
A person may only be an apprentice for two years from the date of first registering with that office.
What term describes a single bulk cylinder of refrigerant after all reclamation is completed?
- Component
- Circuit
- Appliance
- Batch (correct answer)
A batch is defined as a single bulk cylinder of refrigerant after all reclamation has been completed prior to packaging or shipping to the market.
Batch means a single bulk cylinder of refrigerant after all reclamation has been completed prior to packaging or shipping to the market.
Which of the following is considered a component of the refrigerant circuit within an appliance?
- Bulk cylinder
- Compressor (correct answer)
- Retail food store
- Apprentice
A component is a part of the refrigerant circuit within an appliance including compressors, condensers, evaporators, receivers, and all of its connections and subassemblies.
Component means a part of the refrigerant circuit within an appliance including, but not limited to, compressors, condensers, evaporators, receivers, and all of its connections and subassemblies.
What term refers to an appliance that relies on the release of its refrigerant charge to the environment to provide a cooling effect?
- Seasonal variance
- Refrigerant circuit
- One-time expansion device (correct answer)
- Parent company
A one-time expansion device is defined as an appliance that relies on the release of its refrigerant charge to the environment in order to provide a cooling effect.
One-time expansion device means an appliance that relies on the release of its refrigerant charge to the environment in order to provide a cooling effect.
Related practice tests
-
Federal trucking rules practice test (FMCSA) 182 questions, pass mark 80%Practice
-
OSHA construction safety practice test 265 questions, pass mark 70%Practice
Sources
Current text, retrieved November 16, 2026