All tests / FAA aviation mechanic Powerplant knowledge test / Ignition, electrical and starting systems
FAA aviation mechanic Powerplant knowledge test: Ignition, electrical and starting systems practice
122 practice questions on Ignition, electrical and starting systems for the FAA aviation mechanic Powerplant knowledge test. Each answer comes with an explanation and the official source.
Examines high-tension and low-tension magnetos, impulse couplings, spark plug heat ranges, turbine igniters, and starter-generators.
Sample questions
What is the high-tension magneto system still the most widely used aircraft ignition system?
- Battery-ignition system
- Magneto-ignition system (correct answer)
- Low-tension magneto system
- Electronic FADEC system
The high-tension magneto system is still the most widely used aircraft ignition system. Ignition systems can be divided into two classifications: magneto-ignition systems or electronic Full Authority Digital Engine Control (FADEC) systems for reciprocating engines. Ignition systems can also be subclassified as either single or dual magneto-ignition systems.
The high-tension magneto system is still the most widely used aircraft ignition system.
What is the primary electrical circuit composed of in a magneto?
- a breaker cam, a condenser, and a coil
- a condenser, a distributor, and a coil
- a set of breaker contact points, a condenser, and an insulated coil (correct answer)
- a set of breaker contact points, a distributor, and a coil
The primary electrical circuit consists of a set of breaker contact points, a condenser, and an insulated coil. The condenser is wired in parallel with the breaker points. The coil is made up of a few turns of heavy copper wire.
The primary electrical circuit consists of a set of breaker contact points, a condenser, and an insulated coil.
What does the condenser prevent when the circuit is opened at the breaker points?
- a sudden flux reversal
- arcing at the points when the circuit is opened (correct answer)
- a high rate of flux change
- the magnetic field from opposing the permanent magnet’s circuit
The condenser prevents arcing at the points when the circuit is opened. It also hastens the collapse of the magnetic field about the primary coil. This occurs when the circuit is opened.
The condenser prevents arcing at the points when the circuit is opened and hastens the collapse of the magnetic field about the primary coil.
What position must the magneto be in for a spark plug to fire?
- full register position
- E-gap position (correct answer)
- 135° position
- neutral position
The magneto must be in the E-gap position for a spark plug to fire. The E-gap position is reached when the rotating magnet has time to rotate through the neutral position to a point a few degrees beyond neutral. This position is called the E-gap position.
There are three basic events required to fire a spark plug when its piston is in the prescribed position: 1. the magneto must be in the E-gap position, 2. the breaker contact points must be open, and 3. the distributor must be aligned correctly.
What is the external circuit in relation to a DC generator?
- It is the field winding
- It is the armature circuit
- It is the rheostat inserted in series with the field windings
- It is the electrical load powered by the generator (correct answer)
The external circuit is the electrical load powered by the generator. In general, the external circuit is used for charging the aircraft battery and supplying power to all electrical equipment being used by the aircraft.
The external circuit is the electrical load powered by the generator. In general, the external circuit is used for charging the aircraft battery and supplying power to all electrical equipment being used by the aircraft.
Other topics on this test
-
Reciprocating and turbine engines108 questionsPractice
-
Fuel metering, induction and exhaust115 questionsPractice
-
Engine lubrication and cooling systems83 questionsPractice
-
Propellers and governor systems94 questionsPractice
-
Engine installation, fire protection and maintenance195 questionsPractice
Sources
FAA-H-8083-32B, 2023
Questions are written from FAA-H-8083-32B. Check the current Aviation Mechanic Powerplant ACS before testing. ExamVerdict is not affiliated with Federal Aviation Administration (FAA). Check the official material before test day.